Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers. Minimize sample loss by eliminating multiple transfers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon. Preslit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.
Apr 23, 2019 · 0.22 μm 0.45 μm HYDROPHILIC PTFE SYRINGE FILTERS: Virgin PP housing with Hydrophilic PTFE membrane (PP support layer). Diameter 25mm, Pore Size: 0.22μm. HYDROPHILIC PTFE FEATURES: Hydrophilic PTFE membrane has good mechanical strength, tear resistance, the contact angle of less than 20 °, good bubble point , high porosity, high flow rate.
0.45 µm PES 0.2 µm PES 0.45 µm PVDF 0.2 µm PVDF 0.45 µm PTFE 0.2 µm PTFE 0.45 µm Nylon 0.2 µm Nylon Figure 1: The patented design of Thomson SINGLE StEP® filter vials allows you to perform sample clean-up in the same vial that goes into your autosampler. 32 mm 12 mm Dead volume 120 L Fill line volume 450 L Set needle depth to 5 mm from
Clear PTFE (Hydrophobic) Syringe Filters, 0.45 µm, 4 mm (200/Pack) have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation. The pure polypropylene housings are. Related Products: 0.45 Ptfe Filter.
Hamilton PTFE Tip, Gas-Tight Syringes. Suitable for gases or liquids. High accuracy of dispensed volumes. Interchangeable barrels, plungers, and tips extend performance and increase cost-effectiveness. Note: Syringes and needles sold by Restek are intended for scientific research and laboratory use only and are not intended for human in vivo or
PTFE filters can handle degassing and clarifying aqueous samples and filtering strong acid and alkali solvents. Also find PVDF, nylon and MCE filter types. Get syringe filters that can meet your needs at Grainger! Pore Size 0.22 um Note: Product availability is real-time basis and adjusted continuously.
Gravimetric Analysis Membrane Filter, 0.22 µm, mixed cellulose esters with thin pad, 37 mm, white. A 0.22 µm pore size non-sterile filter validated for air monitoring. With biologically inert mixtures of cellulose acetate & cellulose nitrate, MF-Millipore membranes are widely used in analytical & research applications.
Medical Millex-GV Syringe Filter Unit, 0.22 µm, PVDF, 33 mm, gamma sterilized, A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane. Comes in a pack of 50. Expand SLGVV255F Millex-GV Filter, 0.22 µm, A 25 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane.
Description. Rugged polypropylene housing. Autoclavable to 121°C for 15 minutes. Color coded for easy identification. Variety of filter types, porosities, and diameters. Applications. Cellulose Acetate, Nylon, PES, PVDF filters are ideal for hydrophilic applications. PTFE filters are suitable for hydrophobic applications.
High filtration flow rates; An inherently low affinity for proteins. Low extractables; Sterile PTFE Syringe Filters, 0.45(μm), 25(mm), GF prefilter, 100 pack:
Top 9 Reasons to Use Restek Syringe Filters. Protect any analytical system. Extend LC column lifetime. Achieve more reproducible analyses. Variety of membranes, porosities, and diameters available. Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure.
Disc filters, syringe filters, extractors, and bottle top filtration devices have specified diameters for membrane filters. Flow rate: Defined as the time required for the flow stream to pass through the filter, flow rate is critical in determining how rapidly a filtration can be completed. Membrane material, thickness, porosity, and pore
Syringe Filters with Luer Lock Inlet Luer lock inlet offers leak-tight syringe connection. Variety of filter types, porosities, and diameters. Labeled (13, 25, and 30 mm, only) and color coded for easy identification. Rugged polypropylene housing. Autoclavable to 121 °C for 15 minutes. Quantity break pricing for greater savings.
May 21, 2019 · 2.High flow rates and low differential pressures. 3.Rugged PC Housing withstands high temperatures, pressures and aggressive solvents. 4.High particulate-loading capability to maintain flow rates over extended periods. 5.Manufactured in clean room under controlled conditions. 6. Autoclave. 7.Accept ID 7-13 mm tubing. 8.
Syringe filters are attached to the end of a syringe to remove particles from a sample prior to analysis. Filtering liquids, the single-use devices force liquids through the filter either when fluids are initially drawn or delivered. Circular shaped in diameters that fit common syringe sizes, the cartridges remove fragments that would otherwise