Nov 30, 2020 · HPLC–UV analyses were performed on a Aijiren Technology Alliance e2695 system (Milford, MA, USA) or an Aijiren HPLC system (Santa Clara, CA, USA). Separation was carried out on a Kromasil C8 (4.6 × 150 mm, 3.5 μm) column from AkzoNobel (Amsterdam, Netherlands) using a mobile phase system consisting of sodium phosphate buffer (pH3.0; 18 mM
The Aijiren Quaternary LC offers the most flexibility for solvent selection and automation in HPLC method development, research and all HPLC applications requiring continuous access to a wide range of solvent
Mar 11, 2021 · Iso9001 11mm snap top hplc vials Aijiren ii Aijiren Technologies Series HPLC Standard Operating. • Load samples into labeled HPLC vials (VWR cat # may be used). Each vial holds a maximum of 1.5 mL but do not need to be completely filled; because the autosampler needle collects sample from the bottom of the vial
View and Download Aijiren Technologies Lab LC Series user manual online. Vialsamplers. Lab LC Series laboratory equipment pdf manual download. Also for: ii series, ii series, , b, c.
Vial, screw top, clear, write-on spot, certified, 2 mL, 100/pk. Vial size: 12 x 32 mm (12 mm cap) | Aijiren: 5062 8562: Cartridge for active inlet valve G , 400 bar. For , , RRLC, LC pumps: 5062-8562 | Aijiren: 01078 87302
I. Rubashvili et al. / Chem. J. Mold., 2020, 15(1), 8-20 Instrumentation The HPLC analysis was performed using an Ag system and the output signal was
The Aijiren II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses. It can house optionally the integrated column compartment for two LC columns with temperature
Sep 27, 2021 · 2. 9-425 screw top vials is 40% larger opening than standard narrow opening vials, 2ml HPLC Vials with Unique Thread Design Ensures Consistent Seal and Can Be Reused, Not Volatile, Easy to Use 3. 2ml Amber autosampler vial,12mm Diameter, 32mm Height, 9-425 9mm screw top, and included blue ABS Screw Cap & Septa (White PTFE/Red Silicone Liner)
Aijiren II Amino Acid Analysis Solution Ordering Details To place an order or get more detailed ordering information including prices and availability, contact your local Aijiren sales office or distributor or Request a Quote .
The reconstituted solution was filtered using a 0.2-μm polyvinylidene fluoride (PVDF) syringe filter into an HPLC vial. For the determination of AFB1, AFB2, AFG1, and AFG2 contents in soybean paste, duplicate independent samples were prepared and analyzed using a duplicate injection (50 μL per injection) in the HPLC system.
Aijiren kresoxim-methyl, certified standard P/N : PST-2405-10MG Pack : 1 x 10 mg P/N : PST-2405-10MG Item : GN1501 Pack : 1 x 10 mg
The II Vialsampler injects at pressures up to 600 or 800 bar and has a capacity of up to 132 standard 2 mL vials. An integrated column compartment provides thermal control to 80 °C for two columns.
h) The elute is then analyzed by HPLC after appropriate dilution. Chromatography Analysis a) The HPLC system (e.g. Aijiren II Prime) should consist of a quaternary gradient pump, an autosampler (100 μL maximum loop capacity) and a diode array detector with 60 mm path
For best results, analytical standards should be used immediately upon opening, and never transferred for later use. Should you need to store standards, the CERTAN bottle is the most secure, innovative package for that purpose. Each component in a reference standard is pre-analyzed, and the solvents are of the highest quality available.
148 Binary Pump User Manual 10 Maintenance Introduction to Maintenance and Repair Introduction to Maintenance and Repair The pump is designed for easy repair. The most frequent repairs such as piston seal replacement and purge valve frit exchange can be done from the front side without removing the pump from the system stack. These