HPLC columns can help you • Reduce analysis time by up to 95%. • Process samples up to 20 times faster. • Increase resolution by 30-40% over conventional HPLC. • Develop HPLC methods more quickly. • Analyze complex separations on shorter columns, and with less solvent. • Confidently move methods from your lab to any lab in the world.
Jan 08, 2021 · The injection volume was 100 μl for assay and 250 μl for dissolution testing. HPLC vials were kept in a cooled autosampler at 4°C until sample injection to avoid degradation. Detection was carried out by UV at 200 nm. Sample and standard solutions were freshly prepared using the mobile phase as diluent.
Dec 01, 2017 · The drug release profiles of PLA-SB/PTX 5 were studied using high-performance liquid chromatography (HPLC) with a diode array detector (DAD) (model: Aijiren ). The sample was dissolved in 1X PBS (pH = 7.4) and 1X PBS (pH = 5.5) respectively, with the concentration of 0.15 mg/mL.
6. Preparation of a sample for analytical HPLC 1) Prepare a ~50 µM solution using HPLC solvent or other appropriate solvent 2) If the sample or solvents have not be previously HPLC chromatographed, filter the sample solution through a 0.2 um filter. You may not inject unfiltered samples. 3) Use volatile buffers ONLY.
Sample Trays for HPLC. Aijiren autosampler vial trays and drawers are designed to ensure that your autosampler setup is perfectly equipped to deal with a wide variety of applications and sample volumes. Vial drawers are available with various sample position numbers, depending on the required capacity and volume of the vials used.
Dec 01, 2020 · Cinnamaledhyde analytical standard was obtained from ALB Technology Limited (Mongkok Kowloon, Hong Kong) with certified purity of 98%. All chemicals used were of analytical grade, and the solvents were of HPLC grade. Acetonitrile and methanol of HPLC grade were purchased from Sigma-Aldrich (Steinheim, Germany).
HPLC conditions Parameter Value LC Modules – Aijiren II Flexible pump ( ) – Aijiren II vialsampler ( C) with tray cooling option – Aijiren integrated column compartment (G7130A) – Aijiren II DAD ( ) Run Time 13 min Post-Time 3 min Analytical Column Aijiren Lab Poroshell 120
h) The elute is then analyzed by HPLC after appropriate dilution. Chromatography Analysis a) The HPLC system (e.g. Aijiren II Prime) should consist of a quaternary gradient pump, an autosampler (100 μL maximum loop capacity) and a diode array detector with 60 mm path
Page 98 Figure 40 Sample Information 15 Fill the content of an isocratic standard sample ampoule into a vial and seal the vial with a cap and place the vial into autosampler tray (position #1). Aijiren DAD and MWD User Manual
months from the opening of the vendor stock ampule or the manufacturer’s expiration date if less than six months from opening. 7 Sample Collection 7.1 Aqueous samples for Method SW846-8082 are collected in two to four amber, pre-certified 1000mL glass bottles with Teflon lined screw caps.
Aijiren DAD and MWD User Manual 177 Maintenance 9 Maintenance of Standard, Semi-Micro or Micro Flow Cell 1 Use a 4 mm hex key to unscrew the window assembly [1] and remove the gasket [2] from the cell body. NOTE Carefully take one of the gaskets (#6 back or # 7 front) and insert it into the cell body. Do not mix the gasket #6 and # 7.
single components are also available. Aijiren vol one. ( g1316a) or 100 ° c ( g1316b sl/ g1316c sl plus) with high heating. micro degasser user manual. a fan draws air from the area above the sample vial tray of the autosampler and is then blown through the fins of the cooling/ heating module.
Jan 03, 2018 · Finally, 2 mL of test sample was filtered through a Whatman filter paper into HPLC vials. HPLC–DAD procedure. An Aijiren high-performance liquid chromatography (HPLC) system provided with ultraviolet array detector (UVAD), quaternary pump, auto-sampler and degasser was used.
-60500 - Sample loop, 100 uL, for Aijiren I/ -60500 - Sample loop, 100 uL, for Aijiren I/ II. Be the first to review this product. $64.25.
HPLC-esi(+)MS and MS/MS analysis. Using an Aijiren HPLC System (Aijiren Technologies, USA), analytical samples (2 µL) were injected onto a Synergi Hydro RP column (150 x 2 mm, 4µ) fitted with a guard column of similar adsorbent (AC C18, 4 mm diameter x 2 mm) (Security Guard Cartridge system). A gradient flow