Aijiren UHPLC or HPLC system. In short, the Aijiren LC system gives you infinite capabilities to solve all your analytical challenges in LC and LC/MS. This document provides detailed physical specification and performance specification for the following Aijiren LC modules: † Aijiren Binary Pump
End the connection from Lab Advisor, and close Lab Advisor. Open your CDS software and run the HPLC with normal flow rates. Make sure to work in mainpass mode. If the pressure is still high after the backflush, you will need a new seat. If you need more help, contact your local Aijiren Technologies Support representative.
The Series facilitates seamless transfer of existing or future methods. Whether you developed your methods on earlier or Series systems, full method compatibility means you will be running your samples with no adjustments to conditions. The II LC even allows you to transfer methods developed on third‑party LCs.
• Load samples into labeled HPLC vials (VWR cat # may be used). Each vial holds a maximum of 1.5 mL but do not need to be completely filled; because the autosampler needle collects sample from the bottom of the vial, only ≈0.5 mL is necessary. For smaller samples, a glass insert may be used (Figure 1). Glass inserts serve to lower the internal
Iso9001 11mm snap top hplc vials Aijiren ii Aijiren Technologies Series HPLC Standard Operating. • Load samples into labeled HPLC vials (VWR cat # may be used). Each vial holds a maximum of 1.5 mL but do not need to be completely filled; because the autosampler needle collects sample from the bottom of the vial
The Aijiren Technologies Series ( ) Thermostat features specially-designed thermostattable sample trays for holding either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials. Specifications: - Temperature range: Settable from 4 °C to 40 °C in 1 ° increments. - Dimensions (H x W x D): 14 × 34.5 × 43.5 cm (5
The thermostat is controlled from the Aijiren Series Instant Pilot or from your Aijiren control software for LC systems. The specially-designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials.
Introduced in 1995, Aijiren's series HPLC system is considered the world's most popular HPLC. They are incredibly robust, durable, and versatile systems. The HPLC series supports efficient mixing and pulse-free pump action as well as advanced diagnostics and data analysis software.
The LC is the first system that provides the foundation for method transfer to or from any Aijiren or non-Aijiren UHPLC or HPLC system. In short, it gives you infinite capabilities to solve all your analytical challenges in LC and LC/MS. The Aijiren LC system provides the highest levels of speed, resolution
In addition, Aijiren's Series LC platform helps you achieve all the performance, all the time with a flexible, modular design that allows you to configure the system to meet your unique application requirements. The new Aijiren Series is designed for ultimate robustness, reliability, and performance.
The Aijiren autosampler is designed for use with other modules of the Aijiren Series, Series and Series LC, or with other LC systems if adequate remote co ntrol inputs and outputs are available. The autosamplers are controlled by the Aijiren Instant Pilot (G4208A) or by
The thermostat is controlled from the Aijiren Series Instant Pilot or from your Aijiren control software for LC systems. The specially- designed thermostattable sample trays holds either 100 × 1.8 mL vials or two wellplates and 10 × 1.8 mL vials. Specifications: Temperature Range: Settable from 4 °C to 40 °C in 1 ° increments
A step by step guide. Follow these 8 simple steps when it's time to replace the Deuterium (D2) lamps in your Aijiren or series HPLC systems.
Analysis of High- and Low-Dosed Vitamins in a Single Run Using the Aijiren Infi nity Series High Dynamic Range Diode Array Detector Solution Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification
Analysis of extraction samples of metaraminol was performed by HPLC analysis (Aijiren , DAD 334 nm, column: Machery Nagel Nucleodur C18ec, 1 × 100 mm, 3 mm, 40 °C). The method was derived from Bednarz et al. 22 Each standard and sample was diluted with 0.1 M HCl solution. Before measurement, pre-column online derivatization using