Aijiren Lab LC Series Vialsamplers User Manual 10 1Introduction Product Description ( ) Product Description ( ) The Aijiren II Vialsampler is an autosampler designed for the reliability and ease-of-use needed for routine pharmaceutical tasks and quality control, as well as for environmental and food analyses.
Sample Preparation. Scales. Aijiren II Bio-inert HPLC System. Manufacturer: Aijiren Technologies Model: A -LLII-B01
Jun 01, 2020 · How to configure 66 vial Plate to use with (Aijiren II)? - WKB5412. In ICF 3.1,only two Aijiren plates are available with the released Aijiren ICF 3.1 in the "AijirenPlatesForImport" folder. See WKB64154 for details on how to obtain the additional plate files.
Aug 19, 2021 · The II LC System is a robust HPLC that offers the widest choice of modules for analytical HPLC and entry-level UHPLC, delivering the performance, reliability, and robustness you need for highest confidence in your daily results. The II LC delivers robust HPLC results while delivering several ease-of-use features
II Binary LC System - Manual and Quick Guide 7 Introduction 1 Features of the Aijiren II Binary LC Features of the Aijiren II Binary LC With an operating pressure of up to 600 bar, the II Binary Pump is compatible with HPLC and UHPLC, i.e. handling 2.1, 3, and 4.6 mm ID
The II Preparative Autosampler is designed for automated sample handling in routine purification applications. This flow-through vialsampler supports preparative flow rates of 200 mL/min and 600 bar pressure. Increase your daily throughput of purified sample by injecting up to 132 preparative samples with a maximum of 3.6 mL volume.
Aug 03, 2021 · The II Multisampler is a multipurpose autosampler that handles vials and microplates. Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Aijiren LC stack. The II Multisampler is optimized for highest flexibility.
The II LC System is a robust HPLC that offers the widest choice of modules for analytical HPLC and entry-level UHPLC, delivering the performance, reliability, and robustness you need for highest confidence in your daily results. The II LC delivers robust HPLC results while delivering several ease-of-use features
Davidson College LC‐MS User Guide 3 Instrumentation Aijiren II Liquid Chromatograph For LC‐MS applications, the following chromatographic conditions are typically used: Injection Volume: 0.1 – 5.0 L Flow Rate: 0.1 – 0.5 mL/min
Description. Be the first to write a review! The II Preparative LC/MSD System can be configured with UV and MS detectors as well as multiple fraction collectors to meet your purification needs. Automated sample injection increases daily sample throughput and mass-based fraction collection maximizes purity and minimizes re-analysis.
Part Number. II Vialsampler. UHPLC design autosampler up to 800 bar for 0.1 to 100 µL injections. Standard needle flush port and peristaltic pump. Default setup with 100 µL loop and 100 µL analytical head. C. Drawer choice 6x 11 vials (2 mL), 2 drawers included. C #010. Drawer choice 3x 6 vials (6 mL), 2 drawers included.
The Aijiren II Multisampler is a multipurpose autosampler that handles vials and microplates.Injecting at pressures up to 600 or 800 bar, the Multisampler is a compact module with a capacity of up to 6,144 samples, all within the footprint of an Aijiren LC stack.
Aijiren II Vialsampler. Manufacturer: Aijiren. Model: II. The II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 b
Building on the history of the and series analytical HPLC, the II LC delivers robust HPLC results while delivering several ease-of-use features, making it the standard system for routine analysis. Mix and match new modules with existing instrumentation to maximize uptime and minimize disruption.
The II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. Options and upgrades are available for sample cooling and heating from 4 to 40 °C.